Common timeline
Quality
↓
Interpretation
↓
Session record
Independent return pathsSensory cuesElectrical apparatusMagnetic apparatus
EEG / electrical sensingFast scalp-voltage measurements.
Differential contacts and a reference feed isolated acquisition. EEG can support rhythm, event and feature analysis, with eye, muscle and contact references attached to the record.
Contacts→Front end→Timed samples
Electrical stimulation can polarize contacts and overload amplifiers. Recovered, qualified data windows are part of the design.
See the EEG module ↗
MEG / magnetic sensingRead weak magnetic fields.
Optically pumped magnetometers use light and atomic vapor to sense magnetic changes. The station gives the heads a stable mount and reserves space for magnetic references, shielding and field compensation.
Vapor cell→Optical readout→Field estimate
Brain-field sensitivity is a target to verify against a calibrated reference. TMS pulses, nearby actuators and shield remanence can invalidate a window.
See the MEG module ↗
fNIRS / optical physiologyAdd the slower vascular response.
Near-infrared sources and detectors follow relative blood-oxygen changes near the cortical surface. Short paths capture superficial changes; longer paths add some cortical sensitivity.
Light source→Tissue paths→Photodiodes
It complements EEG over a longer timescale. LED drive, ambient light and systemic physiology need their own references.
See the optical methods ↗
Fiber / transportCarry a signal using light.
The analog-link concept turns a buffered electrode voltage into light, stabilizes the emitter with a local photodiode, and recovers the representation at a remote receiver.
EEG buffer→Fiber→Receiver
A pulse-timing link is a separate experimental encoding route. Neither creates a second neural measurement or establishes complete electrical isolation.
Compare the optical roles ↗
Body / referencesKeep the rest of the body in view.
Eye and muscle activity, heartbeat, movement, respiration where instrumented, contact force and fit can explain apparent changes in a brain channel.
Reference sensors→Shared timestamps→Quality flags
Reference channels help test an explanation. Removing a component from a signal does not automatically prove the remainder is neural.
See the reference channels ↗
Environment / contextMeasure the room as well.
Local magnetic references and independent ELF/RF receivers describe interference and environmental signals. Schumann-band reception belongs here as a calibrated field experiment.
Field receiver→Calibration→Context record
Environmental pT instruments are not assumed MEG sensors. Similar frequencies in the room and EEG do not establish biological coupling.
Explore the field hypothesis ↗
Active probe / experimentalMeasure a driven response.
An impedance, resonator or head-loop experiment applies a characterized excitation and asks what changes in phase, damping or transfer properties.
Known excitation→Probe→Response
Driven-response data stays separate from passive EEG/MEG. A repeatable response could reflect contact, temperature or direct pickup.
See the characterization tools ↗