One workspace.
Coordinated instruments.

A supported participant, a removable sensing array, a common session controller and separate output modules. Each instrument keeps its own physics; the station connects their timing and purpose.

Follow a signal

From the participant
to the next observation.

Select an input to see its job in the system. This is an architecture illustration; no instruments are connected.

Common timeline

Quality
↓
Interpretation
↓
Session record

Independent return pathsSensory cuesElectrical apparatusMagnetic apparatus

EEG / electrical sensing

Fast scalp-voltage measurements.

Differential contacts and a reference feed isolated acquisition. EEG can support rhythm, event and feature analysis, with eye, muscle and contact references attached to the record.

Contacts→Front end→Timed samples

Electrical stimulation can polarize contacts and overload amplifiers. Recovered, qualified data windows are part of the design.

See the EEG module ↗
MEG / magnetic sensing

Read weak magnetic fields.

Optically pumped magnetometers use light and atomic vapor to sense magnetic changes. The station gives the heads a stable mount and reserves space for magnetic references, shielding and field compensation.

Vapor cell→Optical readout→Field estimate

Brain-field sensitivity is a target to verify against a calibrated reference. TMS pulses, nearby actuators and shield remanence can invalidate a window.

See the MEG module ↗
fNIRS / optical physiology

Add the slower vascular response.

Near-infrared sources and detectors follow relative blood-oxygen changes near the cortical surface. Short paths capture superficial changes; longer paths add some cortical sensitivity.

Light source→Tissue paths→Photodiodes

It complements EEG over a longer timescale. LED drive, ambient light and systemic physiology need their own references.

See the optical methods ↗
Fiber / transport

Carry a signal using light.

The analog-link concept turns a buffered electrode voltage into light, stabilizes the emitter with a local photodiode, and recovers the representation at a remote receiver.

EEG buffer→Fiber→Receiver

A pulse-timing link is a separate experimental encoding route. Neither creates a second neural measurement or establishes complete electrical isolation.

Compare the optical roles ↗
Body / references

Keep the rest of the body in view.

Eye and muscle activity, heartbeat, movement, respiration where instrumented, contact force and fit can explain apparent changes in a brain channel.

Reference sensors→Shared timestamps→Quality flags

Reference channels help test an explanation. Removing a component from a signal does not automatically prove the remainder is neural.

See the reference channels ↗
Environment / context

Measure the room as well.

Local magnetic references and independent ELF/RF receivers describe interference and environmental signals. Schumann-band reception belongs here as a calibrated field experiment.

Field receiver→Calibration→Context record

Environmental pT instruments are not assumed MEG sensors. Similar frequencies in the room and EEG do not establish biological coupling.

Explore the field hypothesis ↗
Active probe / experimental

Measure a driven response.

An impedance, resonator or head-loop experiment applies a characterized excitation and asks what changes in phase, damping or transfer properties.

Known excitation→Probe→Response

Driven-response data stays separate from passive EEG/MEG. A repeatable response could reflect contact, temperature or direct pickup.

See the characterization tools ↗

A session has phases

Sense. Return.
Recover. Reassess.

The controller coordinates a sequence. Sensitive measurements and powerful outputs have defined windows, with quality flags that follow the data.

EEG + referencesQualified windowCue markersProtect / flagCheck baseline
OPM / MEGQuiet, lockedTest cue pickupExcludedRequalify field
Optical physiologyTimed sourcesTrack trendsMode-specificCheck sources
StimulationOffOffExternal systemOff / verified

Establish the measurement.

Check contacts, noise, sensor lock and field references. Optical sources run only in characterized configurations. This is where usable measurement windows begin.

Train with a traceable cue.

Return a validated feature through a display, remote sound path or qualified haptic module. Log the cue and test whether its hardware disturbs the measurement.

Reserve the intervention window.

A dedicated electrical or magnetic system owns the output. The station records permission, event and independent monitor information while contaminated sensing is excluded.

Earn the next clean window.

Check amplifier recovery, electrode polarization, magnetic baseline and OPM lock. Recovery is measured; a timer alone cannot establish that the data is usable again.

Illustrative sequence, without durations or output parameters. A study can use sensory feedback alone; electrical and magnetic interventions are separate research configurations.

Designed to work together

Compatibility is part
of the architecture.

The station shares timing and geometry while separating power, signal paths and operating modes. Each combination still needs measurement on the actual hardware.

EEG + tDCS / tACS

Protect, then reassess.

Electrical output can overload the front end or polarize electrodes. The first design uses interleaved windows and measured recovery, rather than interpreting the output artifact as EEG.

MEG + tCMS / TMS

Reserve a quiet magnetic scene.

Pulses, coil position and shield remanence can prevent usable MEG. A removable coil arrangement, sensor relocking and field checks may require changing configuration between sessions.

Optics + acquisition

Identify every light path.

fNIRS sources, OPM optics and fiber transport have different jobs. Source timing, detector headroom, drive currents and thermal controls must be characterized together.

Seat + instruments

Keep the geometry stable.

Quiet acquisition reserves the seat and head fixture. Motors, massage, speakers, pumps and metal parts need mode-specific placement and exclusion checks.

Shared control, independent apparatus.

The external stimulator keeps its own limits, stop controls and qualified operator interface. The chair reports pose and fault status; those status signals do not generate TMS pulses. MRI remains an external validation tool.